{"id":2688,"date":"2020-07-15T14:35:47","date_gmt":"2020-07-15T14:35:47","guid":{"rendered":"http:\/\/www.finden.co.uk\/?page_id=2688"},"modified":"2023-06-13T11:33:16","modified_gmt":"2023-06-13T11:33:16","slug":"projects-development-of-chemical-tomography","status":"publish","type":"page","link":"https:\/\/www.finden.co.uk\/zh\/projects-development-of-chemical-tomography\/","title":{"rendered":"\u5316\u5b66\u6210\u50cf\u4e0e\u65ad\u5c42\u626b\u63cf"},"content":{"rendered":"<h3>Chemical imaging &amp; tomography<\/h3>\n<p>Finden works directly with clients on short commissioned projects, but is also involved in long term research projects with clients and partners from across the world. Examples are given below including a case study.<\/p>\n<p><strong>Further case studies include:<\/strong><\/p>\n<p><a href=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-medium wp-image-1775\" src=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-300x169.png\" alt=\"Figure 1 Case Study 3\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-300x169.png 300w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-768x433.png 768w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-1030x581.png 1030w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-705x398.png 705w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1-450x254.png 450w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy3_Fig1.png 1166w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"http:\/\/www.finden.co.uk\/zh\/arriving-at-five-dimensional-diffraction-imaging\/\">Arriving at five dimensional diffraction imaging<\/a><\/p>\n<p>We report the results from the first 5D tomographic diffraction imaging experiment of a complex Ni\u2013Pd\/CeO<sub>2<\/sub>\u2013ZrO<sub>2<\/sub>\/Al<sub>2<\/sub>O<sub>3<\/sub> catalyst used for methane reforming.<\/p>\n<div  class='avia-button-wrap av-13q4p-9b63bb7a5b6b9f4a93d1fbeedc3bb14e-wrap avia-button-left  avia-builder-el-0  el_before_av_button  avia-builder-el-first'><a href='https:\/\/www.finden.co.uk\/zh\/arriving-at-five-dimensional-diffraction-imaging\/'  class='avia-button av-13q4p-9b63bb7a5b6b9f4a93d1fbeedc3bb14e av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'   aria-label=\"Read more\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue822' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >Read more<\/span><\/a><\/div>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-medium wp-image-1769\" src=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-300x129.png\" alt=\"Figure 1 Case Study 2\" width=\"300\" height=\"129\" srcset=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-300x129.png 300w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-768x329.png 768w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-1030x442.png 1030w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-705x302.png 705w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1-450x193.png 450w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy2_Fig1.png 1180w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"http:\/\/www.finden.co.uk\/zh\/developing-the-next-generation-data-collection-strategies-for-x-ray-chemical-imaging\/\">Developing the next generation data collection strategies for x-ray chemical imaging<\/a><\/p>\n<p>An X-ray diffraction computed tomography data-collection strategy that allows, post experiment, a choice between temporal and spatial resolution is reported.<\/p>\n<div  class='avia-button-wrap av-1d48x-693b038416fe86b94e2b305929c284b6-wrap avia-button-left  avia-builder-el-1  el_after_av_button  el_before_av_button'><a href='https:\/\/www.finden.co.uk\/zh\/developing-the-next-generation-data-collection-strategies-for-x-ray-chemical-imaging\/'  class='avia-button av-1d48x-693b038416fe86b94e2b305929c284b6 av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'   aria-label=\"Read more\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue822' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >Read more<\/span><\/a><\/div>\n<p>&nbsp;<\/p>\n<p><a href=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-medium wp-image-1758\" src=\"http:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-300x78.png\" alt=\"Figure 1 for case study 1\" width=\"300\" height=\"78\" srcset=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-300x78.png 300w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-768x199.png 768w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-1030x267.png 1030w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-705x183.png 705w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1-450x117.png 450w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2019\/01\/CaseStudy1_Fig1.png 1372w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"http:\/\/www.finden.co.uk\/zh\/towards-artefact-free-x-ray-diffraction-tomography-images\/\">Towards artefact free-x-ray diffraction tomography images<\/a><\/p>\n<p>This paper reports a simple but effective filtering approach to deal with single\u2010crystal artefacts in X\u2010ray diffraction computed tomography (XRD\u2010CT).<\/p>\n<div  class='avia-button-wrap av-2a0nt-fdcf3466c35a1e5d0f53feac9f605de3-wrap avia-button-left  avia-builder-el-2  el_after_av_button  el_before_av_button'><a href='https:\/\/www.finden.co.uk\/zh\/towards-artefact-free-x-ray-diffraction-tomography-images\/'  class='avia-button av-2a0nt-fdcf3466c35a1e5d0f53feac9f605de3 av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'   aria-label=\"Read more\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue822' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >Read more<\/span><\/a><\/div>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3195 size-medium alignleft\" src=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-300x139.jpg\" alt=\"Phantom sample consisting of four capillaries containing TiO2, SiC and (2x) MgO powders image\" width=\"300\" height=\"139\" srcset=\"https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-300x139.jpg 300w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-1030x479.jpg 1030w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-768x357.jpg 768w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-1536x714.jpg 1536w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-1500x697.jpg 1500w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1-705x328.jpg 705w, https:\/\/www.finden.co.uk\/wp-content\/uploads\/2022\/01\/DLSRPicture-1.jpg 2016w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><a href=\"https:\/\/www.finden.co.uk\/zh\/case-study-enabling-x-ray-diffraction-computed-tomography-xrd-ct-for-large-samples\/\">Enabling X-ray diffraction computed tomography (XRD-CT) for large samples<\/a><\/p>\n<p>Over the past decade XRD-CT has gained a lot of attraction as a materials characterisation technique that allows for spatially resolving the chemistry inside samples in a non-destructive manner. However, one of the limitations of the technique is related to the sample size due to the parallax artefact. The parallax artefact arises from relatively large samples where X-rays, scattered from a scattering angle 2\u03b8, arrive at multiple detector elements. This phenomenon leads to loss of physico-chemical information associated with diffraction peak shape and position (<em>i.e.<\/em> altering the calculated crystallite size and lattice parameter values, respectively) and is currently the major barrier to investigating samples and devices at the centimetre level (scale-up problem). We have developed a new tomographic reconstruction algorithm, termed Direct Least-Squares Reconstruction (DLSR) algorithm, which solves the parallax artefact problem in XRD-CT.<\/p>\n<div  class='avia-button-wrap av-2a0nt-2-406181fb9cb427dcd58bbf5f2034349c-wrap avia-button-left  avia-builder-el-3  el_after_av_button  avia-builder-el-last'><a href='https:\/\/www.finden.co.uk\/zh\/case-study-enabling-x-ray-diffraction-computed-tomography-xrd-ct-for-large-samples\/'  class='avia-button av-2a0nt-2-406181fb9cb427dcd58bbf5f2034349c av-link-btn avia-icon_select-yes-left-icon avia-size-small avia-position-left avia-color-theme-color'   aria-label=\"Read more\"><span class='avia_button_icon avia_button_icon_left avia-iconfont avia-font-entypo-fontello' data-av_icon='\ue822' data-av_iconfont='entypo-fontello' ><\/span><span class='avia_iconbox_title' >Read more<\/span><\/a><\/div>\n<hr \/>\n<p>Read more about our <a href=\"http:\/\/www.finden.co.uk\/zh\/team\/\">team<\/a> and <a href=\"https:\/\/www.finden.co.uk\/zh\/publications\/\">publications<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Chemical imaging &amp; tomography Finden works directly with clients on short commissioned projects, but is also involved in long term research projects with clients and partners from across the world. Examples are given below including a case study. Further case studies include: Arriving at five dimensional diffraction imaging We report the results from the first [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"class_list":["post-2688","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/pages\/2688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/comments?post=2688"}],"version-history":[{"count":19,"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/pages\/2688\/revisions"}],"predecessor-version":[{"id":3610,"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/pages\/2688\/revisions\/3610"}],"wp:attachment":[{"href":"https:\/\/www.finden.co.uk\/zh\/wp-json\/wp\/v2\/media?parent=2688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}